ART042 – Solar – Centaur / Taurus Pressure & temp control block.
Solar – Centaur / Taurus pressure & temperature control block PN190185. This article discusses the issues and experiences of operators. Continue Reading →
FT8 & Solar – Turbine Technical Information
Training and Troubleshooting documentation and videos.
Solar – Centaur / Taurus pressure & temperature control block PN190185. This article discusses the issues and experiences of operators. Continue Reading →
Solar Turbines – T60 – G353-1 backup overspeed calibration. Continue Reading →
ARTICLE REF – ART011 Alignment shim calculation T60 mobile unit The following information will serve you on all alignment jobs regardless of the manufacturer. It is very important to have a good understanding of what shims need to be put where when it comes to making an alignment adjustment. This … Continue Reading →
ARTICLE REF – ART010 Part 2 Alignment information sources. Alignment tools and setup. Three readings to satisfy spec. Torque values. Alignment information sources. Mechanical Installation Drawing 149223. Chapter 9.5 of the maintenance manual (IMI). Installation guideline No. TPIM 1000B. Alignment tools and setup. This is the type of tool you … Continue Reading →
ARTICLE REF – ART009 Part 1 Total Indicator Reading. Soft Foot. Changing target sides. Bore and RIM Readings. Magnetic center. Hub to hub distance. Tool sag. TIR – Total Indicator Reading Question: The dial test indicator (DTI) is zeroed at the 12-o-clock position. The shaft on the right is turned … Continue Reading →
Taurus 60 IGV training video. Continue Reading →
This video explains what is Alignment TIR. Continue Reading →